Collecting Diagnostic Information for Huawei Switch

Huawei switch supports rich and flexible service features and thus improves the operability, manageability, and service expansibility. The Huawei switches include Huawei data center switches, campus switches (Huawei S9700, S7700, S6700, S5700, S3700, S2700, S9300, S6300, S5300, S3300, S2300 series) and SOHO&SMB switches (Huawei S1700 series), fully meeting enterprise and telecom customers' requirements for flexible networking. Here we will tell you the method to collect diagnostic information for Huawei switches.

The display diagnostic-information command provides outputs of multiple commonly used display commands. You can use this command to view diagnostic information about the switch, including the startup configuration, current configuration, interface information, time, and system version.
The display diagnostic-information [ file-name ] command displays the device diagnostic information on screen or saves the information to a text file (.txt). The device diagnostic information includes startup configuration, current configuration, interface information, time, and system version. The following is an example:
<HUAWEI> display diagnostic-information dia-info.txt
  This operation will take several minutes, please wait.........................
................................................................................
...                                                                             
Info: The diagnostic information was saved to the device successfully.
The default path of the text file is flash:/. You can run the dir command in the user view to check whether the text file has been created.
When a fault occurs on the switch, provide the diagnostic information to the Huawei agent or Huawei immediately for fast fault location.
If diagnostic information is displayed on the screen, you can press Ctrl+C to stop the display any time.
This command is used to collect diagnostic information for fault location. Executing this command may affect the system performance. For example, it may cause a high CPU usage. Therefore, do not run this when the switch is running normally. Do not run this command on multiple terminals connected to the switch at the same time. Otherwise, the CPU usage of the switch will increase sharply, causing system performance deterioration.
NOTE:
All the commonly used terminal configuration programs can save display information to a file. For example, if you are using HyperTerminal on a Windows operating system, choose Transfer > Capture Text, enter a file name, and then click Start. After that, run the display diagnostic-information command. All the diagnostic information is displayed on the terminal screen and automatically saved in a file in the specified path.
The more information about technical support you can consult with our engineer the e-mail address is as below:

More related:

2014年9月17日星期三

The difference between the Huawei S2700SI and S2700EI



Q: What is the difference between S2700-9TP-EI-AC and S2700-9TP-SI-AC?

A: Please refer to below list:
Features
ACL
Yes
No
QINQ
Yes
No
RRPP
Yes
No
MFF
Yes
No
MSTP
Yes
No
802.1X
Yes
No
DAI
Yes
No
IPSG
Yes
No
OAM
Yes
No

Huawei Quidway S2700 series Fast Ethernet enterprise switch is highly scalable and energy-efficient, work as 100 Mbit/s access switches. Huawei S2700 meets the demand for multi-service provisioning and access on Ethernet networks. It is easy to install and maintain and can be used in a variety of enterprise network scenarios. With S2700 flexible VLAN deployment, comprehensive security and QoS policies, and energy-saving technologies, the S2700 helps enterprise customers build next-generation IT networks. Huanetwork keeps many S2700 switches in stock and can ship to worldwide.

The more information about the Huawei switch, you can visit: www.huanetwork.com, a world leading Huawei networking products distributor, it always devotes to satisfying clients' needs, is a platform for us to learn and share knowledge!



More related:

2014年7月11日星期五

What Optical Modules Do S1700 Switches Support?



ESFP-GE-multimode module (850 nm,
0.5 km, LC)
ESFP-GE-single-mode module (1550 nm, 40
km, LC)
SFP-GE-single-mode module (1310 nm,
10 km, LC)
ESFP-GE-single-mode module (1550 nm, 80
km, LC)
ESFP-GE-single-mode module (1310 nm,
40 km, LC)
ESFP-GE-single-mode module (1550 nm,
100 km, LC)
ESFP-GE-single-mode module (1550 nm,
100 km, LC)
ESFP-GE-single-mode module (1550 nm, 40
km, LC)
SFP-GE-BIDI single-mode module
(TX1490/ RX1310, 10 km, LC)
SFP-GE-BIDI single-mode module
(TX1310/RX1490, 10 km, LC)

The comment question about the huawei S1700, maybe you want to know, plesae read as below:

Q1: Can S1700 be managed by U2000 or eSight?
A1: The S1700 series switches cannot be managed by U2000 or eSight.

Q2: What is the operating temperature range of S1700 switches?
A2: The operating temperature range of S1700 switches is 0°C to 45°C.

Q3: Why does the diskless workstation fail to start after STP is enabled on an S1700 web-managed switch?
A3: To solve this problem, configure the service port of the switch connected to the diskless workstation as an edge port. For details, see the user guide of the web network management system.

Q4: How many types do S1700 switches have? How can these types be differentiated? How Can I log in to these switches?
A4: The S1700 switches are classified into NMS-free, web-managed, and web/SNMP-managed switches, as listed in the following table. Use the IP addresses, user names, and passwords provided in the table to log in to the switches.
Type
Model
Default IP
Address
UserName/Password
NMS-free switch
NA
NA
Web-managed switch
196.168.0.1
admin/admin
Web/SNMP-managed
switch
192.168.1.25
3
admin/admin

2014年4月29日星期二

S2700/S3700/ S5700 Switch PoE Power Supply

What Are the Differences Between a PoE Power Supply Unit and a Common Power Supply Unit on a Quidway S2700/S3700/ S5700 Huawei Switch?

Answer:
On a S2700/S3700/S5700 switch, a PoE power supply unit and a common power supply unit differ in their appearance and functions.
l Figure 1-1, Figure 1-2, and Figure 1-3 show their appearance. A PoE power supply unit
has a fan, but a common power supply unit does not.

Figure 1-1 Common power supply unit
Figure 1-2 250 W PoE power supply unit
Figure 1-3 500 W PoE power supply unit
A PoE power supply unit can provide power for both the entire device and the PDs, whereas a common power supply unit can provide power for only the entire device.

More topic about Huawei S5700: