Huawei S9300: Example for Logging In to the Device Through a Console Port

Huawei S9300: Example for Logging In to the Device Through a Console Port
Networking Requirements
When you cannot remotely log in to the device, you can perform local login through a console port. If you log in to the device through a console port, only password authentication is required. To improve security, use AAA on the console user interface.

Configuration Roadmap
The configuration roadmap is as follows:
1. Use the terminal simulation software to log in to the device through a console port.
2. Configure the authentication mode of the console user interface.

Procedure
Step 1 Use the terminal simulation software to log in to the device through a console port.
1. Insert the DB9 connector of the console cable delivered with the product to the 9-pin serial port on the PC, and insert the RJ45 connector to the console port of the device, as shown in Figure 2.

2. Start the terminal simulation software on the PC. Establish a connection, and set the
connected port and communication parameters.

NOTE
A PC may have multiple connection ports; therefore, the port connected through the console cable is selected in this example. Generally, COM1 is selected.
If the serial port communication parameters of the device are modified, modify the communication parameters on the PC accordingly (ensure that the parameter values are the same) and re-establish the connection.

3. Press Enter until the system prompts you to enter the password. (The system will prompt you to enter the user name and password in AAA authentication. The following information is only for reference.)

Login authentication
Password:

You can run commands to configure the device. Enter a question mark (?) whenever you
need help.

Step 2 Configure the authentication mode of the console user interface.
<Quidway> system-view
[Quidway] user-interface console 0
[Quidway-ui-console0] authentication-mode aaa
[Quidway-ui-console0] user privilege level 15
[Quidway-ui-console0] quit
[Quidway] aaa
[Quidway-aaa] local-user huawei password cipher Huawei@123
[Quidway-aaa] local-user huawei privilege level 3
[Quidway-aaa] local-user huawei service-type terminal
After the preceding operations, you can re-log in to the device on the console user interface only
by entering the user name huawei and password Huawei@123.
----End

Configuration Files
#
aaa
local-user huawei password cipher %$%$]*6iWr7EVM|uc:"B/A=FF}tk%$%$
local-user huawei privilege level 3
local-user huawei service-type terminal
#
user-interface con 0
authentication-mode aaa
user privilege level 15
#

return
The popular huawei S9300 switch, please click the below links:

2014年2月13日星期四

The switch failure troubleshooting steps (3)

3, general troubleshooting steps for switch failure: such as S5700-28P-PWR-LI-AC and S3700-52P-EI-24S-AC, as I use them most time.
Fault switch diversity, different faults have different forms. Failure analysis to the various phenomena of flexibility in the use of elimination method (such as the exclusion of hair,comparative method, substitution method), locate the faults, and excluded in a timely manner.
(1) elimination method:
When we face failure phenomena and analyze problems, inadvertently will have learned to use exclusion method to determine the fault direction. This method refers to the fault phenomenonon the basis of the observed, as comprehensive as possible to enumerate all possible faults,and then analyzed, excluding. In the rule to follow is simplicity to complexity, improve the efficiency of. Fault using this method can deal with all kinds of maintenance personnel, but needstrong logical thinking, have a comprehensive understanding to exchange knowledge.
(2) contrast method:
The so-called contrast method, is to use existing, the same model and to the normal operation of the switch as a reference object, make the comparison between the switch and fault, so as tofind the point of failure. The method is simple and effective, especially the fault systemconfiguration, simply compare can identify different point configuration, but sometimes to findmodels of the same configuration, the same switch is not an easy thing.
(3) the replacement method:
This is the most commonly used method, method is used frequently in the repair of computer.Replacement method refers to replace faulty components use may switch components of normal, to find the fault point. It is mainly used for hardware diagnostics, but need to pay attention to is, replacement parts must be the same brand, same type of similar switch caixing.
Of course, in order to make the pilot work of rule-based, we can in the fault analysis, in accordance with the following principles to analyze.
1, from far to near
Because of the general applause switch (such as: port fault) are discovered by the connectionfrom the client computer, so often to check. We can follow the client computer - > port module - > horizontal cable - > jumper - > switch such a route, inspect, first remove the remote fault may.
2, from outside to inside
If the switch faults exist, we can first light from the various external, then according to the fault indicator, then check whether the corresponding components of internal problems. For example,the POWER LED light indicates the power supply is normal, put out that no power supply; LINKLEDs yellow said it the connection in 10Mb/s, green is 100 Mb/s, extinguished said there was noconnection, flashes that port is closed manually administrator RDP LED said; redundant power supply; MGMT LED said the administrator module. Whether from the outside of the fault lies,must log switch to determine the specific problem, and troubleshooting measures.
3, from soft to hard
Failure, who do not want to touch the screwdriver to open the switch again, so at the time of the inspection, always start with the system configuration or system software to check. If the software does not solve the problem, and that is hardware problem. For example, a port is notgood, we can check the user connection port is not in the corresponding VLAN, or whether the port is to shut down the rest of the administrator, or configuration for other reasons. If theexclusion of various system and configuration may be, it can be suspected that the real problem-- a hardware failure.
4, from easy to difficult
In the face of failure analysis is more complex, must start from the simple operation or configuration to exclude. This can speed up the speed of troubleshooting, improve efficiency.
Summary:

As a result of a variety of switch failure phenomenon of diversity, there is no fixed rule steps,and some failures tend to have a clear direction, can identify. So can only be based on theconcrete analysis of concrete conditions. So need to improve yourself, to complete the task of network management better.


2014年2月12日星期三

The switch failure troubleshooting steps (2)

2, software failure for switch:
Software fault switch is refers to the fault system and its configuration, it can be divided into the following categories.
(1) the system error:
Switch system is the combination of hardware and software. There is a refresh read only memory in the switch, it is necessary to save the software system which switches. This kind ofmistake and our common Windows, like Linux, due to the design, there are some loopholes, inthe right conditions, can cause packet loss, packet switch, load fault conditions. So the switch system provides such as Web, TFTP to download and update system. In the course of theupgrade of the system, it may cause an error.
For such problems, we need to develop the habit of often browse equipment manufacturers website habits, if a new system or new patch, please update.
(2) improper configuration:
Beginners are not familiar with the switch, or because of various kinds of switch configuration is not the same, administrators often occurs in configuring the switch configuration error. For example, VLAN partition due to incorrect network impassability, port is mistakenly closed model,configure the switch and network card does not match. This kind of fault is sometimes hard tofind, need certain experience accumulation. If you can't ensure user configuration problem,please restore factory default configuration, and then configure the step by step. The bestbefore configuration, first read the instruction, one of which is to develop the habit of network management. Each switch has the installation manual, detailed user manual, into each modulehas a detailed explanation. Because a lot of switch manual is written by English, so English bad user can show the supplier engineer after the Advisory specific configuration.
(3) lost password:
This may be each administrator has ever experienced. If you forget your password, can through the operation of certain steps to recover or reset the system password. Some are relativelysimple, press a button on the switch can be. While others need to be resolved by the steps to a certain.
This kind of situation in general artificial forgotten or switch failure cause data loss occurs.
(4) external factors:
Because the virus or hacker attack conditions exist, there may be a host to send the connectionport number is not in conformity with the encapsulation rules packet switch processor, cause too busy, the data packet not forwarding, which led to the emergence of packet loss phenomenon of buffer overflow. There is a situation in which the broadcast storm, it will not only occupy a large amount of network bandwidth, but also will occupy the CPU a lot of processing time. Network iflong time is occupied by a large number of broadcast packets, the normal point ofcommunication can not be normal, network speed will be slow or paralysis.
A card or a port failure, are likely to cause broadcast storm. Because the switch can onlyseparate collision domains, but can not break up broadcast domains (no division in the case of VLAN), so when the number of broadcast packets accounted for 30% of the totalcommunication, network transmission efficiency will be decreased.

Rather than hardware failure is difficult to find in general software fault, problem solving, may not need to spend too much money, but need more time. It is best to develop the habit of recordinglog in daily work. Whenever fault occurs, completes the fault phenomenon, fault analysis, faultrecording process solutions, fault classified summary of work in a timely manner, to accumulatetheir experience. For example, sometimes in the configuration, due to various reasons, there was no influence on network or found no problem, but perhaps a few days later the problem willgradually appear. If the log records, you can associate a few days before the configurationerror. Because a lot of time will ignore this point, thought is the problem on the other hand, whenafter many detours, to find the problem. So the log records and the maintenance of informationis very necessary.
The switches S5700-52C-PWR-EI, S5700-52C-EI are on sale for huanetwork.com.

The switch failure troubleshooting steps (1)

Switch the superior performance and the decreasing prices, contributed to the rapid popularization of switch. Switch fault network administrator will often encounter a variety in the work, how quickly, find out the fault accurately and troubleshooting? This paper makes a brief introduction on the common faults and troubleshooting steps. Because the switch in the network in a very wide range of applications, from low-end to mid-range, from end to end, involving almost every level of product, so the switch failure probability than the router, firewall is much higher, which is why we first discuss the classification of switch failure and troubleshooting steps.
1 fault classification of switch :
Can generally be divided into hardware and software fault two kinds of switch failure. Hardware failure mainly refers to the fault switch power, backplane, module, port and other components,can be divided into the following categories.
(1) the power failure:
Because of the external power supply is not stable, or power lines aging or lightning causedpower failure or the fan stops, so does not work. Damage to other components inside the machine frequently happens due to power.
If the panel on the POWER indicator light is green, that is normal; if the light is off, the switch is not normal power supply. This kind of problem is very easy to find, is also very easy to solve, but also the most preventable.
In view of this kind of failure, should first do the external power supply, the general to provide independent power supply through a power line into independent, and add the voltage regulator to avoid the instant high voltage or low voltage phenomenon. If conditions permit, you can add a UPS (uninterruptible power supply) to ensure the normal power supply switch, some UPSregulator function, and some not, choose to pay attention to. The measure of the lightning protection of professional settings in the engine room, to avoid damage to the switch of lightning. There are many do lightning protection engineering Professional Company, can consider to implement network wiring.
(2) port failure:
This is the most common hardware failure, both optical port or twisted pair RJ-45 port, plug inconnector must be careful. If you accidentally put the fiber optic plug dirty, may cause fiber portpollution but not normal communication. We often see a lot of people like electric plugconnector, the theory is possible, but it also inadvertently increased port failure rate. Not carefulin handling, may also cause the port physical damage. If the first crystal size buy slants big, into the switch, also easy to destroy the port. In addition, if the twisted pair is connected to the porthas an exposed outdoors, if this cable to be struck by lightning, will cause the connected switch port damaged, or cause more unexpected injury.
In general, port fault is one or several port damage. So, after exclusion of port connectedcomputer failure, can port connected through the replacement, to determine whether the damage. Encounter this kind of failure, can be in after the power is turned off, with alcohol cotton ball cleaning port. If the port is damaged, it will only change the port.
(3) module failure:
The switch is composed of many modules, such as: the stack module, management module(also called control module expansion module), etc.. A very small chance these module is in trouble, but if there is a problem, will suffer huge economic losses. If the plug-in moduleaccidentally, or handling switches by collision, or power supply is not stable, there may lead tosuch failure.
The 3 module course mentioned above have the external interface, is easy to identify, and some also can through the indicating lamp on the module to identify the fault. For example: atrapezoidal port a flat stack module, or switch is an interface similar to USB. Management module has a CONSOLE port, connection establishment and management for the computer,convenient management. If an extension module is optical fiber connection, there will be a pair of optical fiber interface.
In the exclusion of such failure, the first to ensure the normal power supply and switch module,then check each module is inserted in the correct position, finally check the connection modulecable is normal. In the connection manager module, consider whether it uses the connectionrate regulations, if there is a parity check, whether the data flow control etc.. Connectionmodule, need to check whether the matching mode of communication, such as: the use of full duplex or half duplex mode. Of course, if the confirmation module failure, there is only one solution, that is should immediately contact suppliers to replace.
(4) the backplane failure
Each module switches are connected to the backplane. If the environment is wet, damp or shortcircuit boards, components due to high temperature, lightning strikes and other factors and damage will cause the circuit board can not work normally. For example: the coolingperformance is not good or the environment temperature is too high causing the temperature inside the machine increased, instigate burning out of components.
In the external power supply, if the internal module switches are not working properly, it may beback out, encountered such a situation even electric appliance repair engineer, would be put in a quandary, the only way is to replace the backplane.
(5) the cable fault:
In fact, this kind of fault in theory, does not belong to the fault of the switch itself, but in practical use, the cable fault often leads to switch system or port can not work normally, so here is the faultin the switch hardware fault. For example, connector plug is not tight, cable production ordererrors or irregularities, cable should cross line was using the straight line connecting two optical fibers, cables in the cross connection, the wrong line connected to network loop etc..
From several hardware failure above, computer room environment can easily lead to a variety ofhardware failures, so we in the construction of the engine room, you must first make buildinglightningproof grounding and power supply, the indoor temperature, indoor humidity, anti electromagnetic interference, anti - static environment, provide a good environment for thenormal operation of network equipment.
The huawei switch you may want to know, please click the below links:


2014年2月10日星期一

MA5603T: TC-C6212 ONU Failure to Go Online

TC-C6212 ONU Failure to Go Online Because of Incorrect Fiber Connection. This topic describes how to troubleshoot the fault of ONU registration failure.

Fault Description
Network topology: Optical split level: one level; split ratio: 1:16; backbone fiber: 3.2 km long; branch fiber: 600 m long
During deployment in an office, an ONU fails to register with the OLT. The ONU receive optical power is 1.27 dBm and its transmit optical power is -15.9 dBm. The fault persists after system restart or soft system reset.

Alarm Information
None

Possible Cause
l The ONU receive optical power is larger than the overload optical power.
l The ONU receive optical power is smaller than the sensitivity.
l There is abnormal attenuation on ODN lines.
l The fiber is incorrectly connected.

Procedure
Step 1 Test the ONU receive optical power. The ONU receive optical power is -15.9 dBm, which is within the normal range.

Step 2 Perform a remote query. It is found that the ONU should be connected to another PON port.
Then, it is determined that the optical fiber is incorrectly connected.

Step 3 Confirm the connection on site. It is found that the optical fiber is incorrectly connected, as shown in Figure 7-2.
Figure 1 Fiber connection


Step 4 After the fault is rectified, services recover.

Step 5 Such a fault does not recur in the next week.
----End

Suggestion and Conclusion

Identify different ports using labels in engineering and manage the ports differently to prevent incorrect connection.

Customers interested in purchasing Huawei MA5600 or the price, please refer to below links:

MA5603T: Failure to Go Online of an ONU

MA5603T: Failure to Go Online of an ONU, below is the reason analysis and solution. 
The ONU going online failure is a fault in which an ONU fails to go online normally, and the queried Run state of the ONU is displayed as offline by running the display ont info command on the OLT.
Fault Description
Network topology: Optical split level: two levels; level-one split ratio: 1:2; level-two split ratio: 1:16; backbone fiber: 2.2 km long; branch fibers: 500 m to 24 km long
During deployment in an office, the receive optical power of all ONUs under two-level optical splitters is normal but the ONUs fail to go online.

Alarm Information
None

Possible Cause
l The ONU receive optical power is larger than the overload optical power.
l The ONU receive optical power is smaller than the sensitivity.
l There is abnormal attenuation on ODN lines.
l The distance between the ODN Max. receive optical power and Min. optical power exceeds the threshold.

Procedure
Step 1 Analyze the network. It is found that the distance between the farthest ONU and the OLT is over 20 km and the distance between the farthest and nearest ONUs is also over 20 km, as shown in Figure 1.

Step 2 Plan the ODN again and connect the ONUs whose fibers are longer than 20 km to another PON port. Then, ONUs normally go online.
Step 3 Such a fault does not recur in the next week.
----End

Suggestion and Conclusion
Make sure that the distance between the farthest ONU and the nearest ONU under a PON port is smaller than 20 km.
The similar products MA5683T also works for this solution.