TC-C6212 ONU Failure to Go Online Because of Incorrect Fiber
Connection. This topic describes how to troubleshoot the fault of ONU
registration failure.
Fault Description
Network topology: Optical split level: one level; split
ratio: 1:16; backbone fiber: 3.2 km long; branch fiber: 600 m long
During deployment in an office, an ONU fails to register
with the OLT. The ONU receive optical power is 1.27 dBm and its transmit
optical power is -15.9 dBm. The fault persists after system restart or soft
system reset.
Alarm Information
None
Possible Cause
l The ONU receive optical power is larger than the overload
optical power.
l The ONU receive optical power is smaller than the
sensitivity.
l There is abnormal attenuation on ODN lines.
l The fiber is incorrectly connected.
Procedure
Step 1 Test the ONU
receive optical power. The ONU receive optical power is -15.9 dBm, which is within
the normal range.
Step 2 Perform a
remote query. It is found that the ONU should be connected to another PON port.
Then, it is determined that the optical fiber is incorrectly
connected.
Step 3 Confirm the
connection on site. It is found that the optical fiber is incorrectly connected,
as shown in Figure 7-2.
Figure 1 Fiber connection
Step 4 After the fault
is rectified, services recover.
Step 5 Such a fault
does not recur in the next week.
----End
Suggestion and Conclusion
Identify different ports using labels in engineering and
manage the ports differently to prevent incorrect connection.
Customers interested in purchasing Huawei MA5600 or the price, please refer to below links:
没有评论: