The switch failure troubleshooting steps (1)

Switch the superior performance and the decreasing prices, contributed to the rapid popularization of switch. Switch fault network administrator will often encounter a variety in the work, how quickly, find out the fault accurately and troubleshooting? This paper makes a brief introduction on the common faults and troubleshooting steps. Because the switch in the network in a very wide range of applications, from low-end to mid-range, from end to end, involving almost every level of product, so the switch failure probability than the router, firewall is much higher, which is why we first discuss the classification of switch failure and troubleshooting steps.
1 fault classification of switch :
Can generally be divided into hardware and software fault two kinds of switch failure. Hardware failure mainly refers to the fault switch power, backplane, module, port and other components,can be divided into the following categories.
(1) the power failure:
Because of the external power supply is not stable, or power lines aging or lightning causedpower failure or the fan stops, so does not work. Damage to other components inside the machine frequently happens due to power.
If the panel on the POWER indicator light is green, that is normal; if the light is off, the switch is not normal power supply. This kind of problem is very easy to find, is also very easy to solve, but also the most preventable.
In view of this kind of failure, should first do the external power supply, the general to provide independent power supply through a power line into independent, and add the voltage regulator to avoid the instant high voltage or low voltage phenomenon. If conditions permit, you can add a UPS (uninterruptible power supply) to ensure the normal power supply switch, some UPSregulator function, and some not, choose to pay attention to. The measure of the lightning protection of professional settings in the engine room, to avoid damage to the switch of lightning. There are many do lightning protection engineering Professional Company, can consider to implement network wiring.
(2) port failure:
This is the most common hardware failure, both optical port or twisted pair RJ-45 port, plug inconnector must be careful. If you accidentally put the fiber optic plug dirty, may cause fiber portpollution but not normal communication. We often see a lot of people like electric plugconnector, the theory is possible, but it also inadvertently increased port failure rate. Not carefulin handling, may also cause the port physical damage. If the first crystal size buy slants big, into the switch, also easy to destroy the port. In addition, if the twisted pair is connected to the porthas an exposed outdoors, if this cable to be struck by lightning, will cause the connected switch port damaged, or cause more unexpected injury.
In general, port fault is one or several port damage. So, after exclusion of port connectedcomputer failure, can port connected through the replacement, to determine whether the damage. Encounter this kind of failure, can be in after the power is turned off, with alcohol cotton ball cleaning port. If the port is damaged, it will only change the port.
(3) module failure:
The switch is composed of many modules, such as: the stack module, management module(also called control module expansion module), etc.. A very small chance these module is in trouble, but if there is a problem, will suffer huge economic losses. If the plug-in moduleaccidentally, or handling switches by collision, or power supply is not stable, there may lead tosuch failure.
The 3 module course mentioned above have the external interface, is easy to identify, and some also can through the indicating lamp on the module to identify the fault. For example: atrapezoidal port a flat stack module, or switch is an interface similar to USB. Management module has a CONSOLE port, connection establishment and management for the computer,convenient management. If an extension module is optical fiber connection, there will be a pair of optical fiber interface.
In the exclusion of such failure, the first to ensure the normal power supply and switch module,then check each module is inserted in the correct position, finally check the connection modulecable is normal. In the connection manager module, consider whether it uses the connectionrate regulations, if there is a parity check, whether the data flow control etc.. Connectionmodule, need to check whether the matching mode of communication, such as: the use of full duplex or half duplex mode. Of course, if the confirmation module failure, there is only one solution, that is should immediately contact suppliers to replace.
(4) the backplane failure
Each module switches are connected to the backplane. If the environment is wet, damp or shortcircuit boards, components due to high temperature, lightning strikes and other factors and damage will cause the circuit board can not work normally. For example: the coolingperformance is not good or the environment temperature is too high causing the temperature inside the machine increased, instigate burning out of components.
In the external power supply, if the internal module switches are not working properly, it may beback out, encountered such a situation even electric appliance repair engineer, would be put in a quandary, the only way is to replace the backplane.
(5) the cable fault:
In fact, this kind of fault in theory, does not belong to the fault of the switch itself, but in practical use, the cable fault often leads to switch system or port can not work normally, so here is the faultin the switch hardware fault. For example, connector plug is not tight, cable production ordererrors or irregularities, cable should cross line was using the straight line connecting two optical fibers, cables in the cross connection, the wrong line connected to network loop etc..
From several hardware failure above, computer room environment can easily lead to a variety ofhardware failures, so we in the construction of the engine room, you must first make buildinglightningproof grounding and power supply, the indoor temperature, indoor humidity, anti electromagnetic interference, anti - static environment, provide a good environment for thenormal operation of network equipment.